6: Managing Connections
64 Verint Video Solutions
2. Select a transmitter in the left column and a receiver in the
right one.
In the Transmitters column, you have access to the two
encoders of each input. The video stream is the same for
both.
If you are using the web interface on an S1600e, S1700e,
or S2500e device, use Stream2 for the point-to-point
connection.
3. To disable I/O data transmission, clear Forward I/O.
4. To disable serial port data transmission, clear Forward
Serial Port Data.
Warning: You must clear this box if the transmitter is an
S2500e IP camera, since it does not have a serial
port.
5. To enable audio between the devices, ensure that Enable
Audio is checked, then select the audio mode.
6. Click Connect.
You should now have video on the monitor connected to the
receiver device.
Removing a Connection
You can remove an existing point-to-point connection between
two devices. Removing a connection means that no more data
will be transmitted between the two.
To remove a connection:
1. In the Active Connections box of the Connections tab,
select a connection, then click Remove.
A confirmation window appears.
2. Click OK.